Vaillant · Air source heat pump
Vaillant aroTHERM plus
VWL 125/6 A 230V · 12 kW size · single-phase
A single-phase R290 monobloc air-to-water heat pump from the aroTHERM plus /6 generation, sold in the UK as the 12 kW size. Vaillant’s newer aroTHERM plus is a different model.
Outdoor unit only. Required controls and indoor parts are listed below.
Your comparison shortlist
Specifications
Checked .
- What this listing is
- Outdoor unit (monobloc) ↗
- Size as marketed
- Marketed as 12 kW ↗
- Also needed indoors
- Outdoor unit with heat pump interface only. A Vaillant control (such as sensoCOMFORT), a hot water cylinder or uniTOWER indoor unit, and other system parts are needed and sold separately. ↗
- Heat output at 7 °C outside, 35 °C flow (kW)
- 8.5 Nominal output, outdoor air 7 °C, flow 35 °C (EN 14511); output can range from 5.4 to 14.0 kW at this condition ↗
- Heat output at 7 °C outside, 55 °C flow (kW)
- 9.1 Outdoor air 7 °C, flow 55 °C (EN 14511) ↗
- Heat output at 2 °C outside, 35 °C flow (kW)
- 5.9 Outdoor air 2 °C, flow 35 °C (EN 14511) ↗
- Heat output at −7 °C outside, 55 °C flow (kW)
- Not confirmed
- Seasonal efficiency (SCOP), 35 °C flow
- Not confirmed
- Seasonal efficiency (SCOP), 55 °C flow
- Not confirmed
- COP at 7 °C outside, 35 °C flow
- 5.4 Outdoor air 7 °C, flow 35 °C (EN 14511) ↗
- COP at 2 °C outside, 35 °C flow
- 4.6 Outdoor air 2 °C, flow 35 °C (EN 14511) ↗
- Energy label, 35 °C flow
- Not confirmed
- Energy label, 55 °C flow
- A++ Seasonal space heating class, average climate, 55 °C application ↗
- Refrigerant
- R290 (propane) ↗
- Sound power (dB(A))
- 58 Sound power, EN 12102 / EN 14511, heating at outdoor air 7 °C, flow 35 °C (60 dB(A) at flow 55 °C) ↗
- Sound pressure (dB(A))
- Not confirmed
- Maximum flow temperature (°C)
- 75 Heating water temperature range 20 to 75 °C ↗
- Lowest outdoor operating temperature (°C)
- -25 Heating mode works at outdoor temperatures of -25 °C to 43 °C ↗
- Electricity supply
- Single-phase 230 V, 50 Hz ↗
- Dimensions, H × W × D
- 1,565 × 1,100 × 450 mm Height × width × depth ↗
- Weight (kg)
- 194 Ready for operation ↗
- Warranty
- Not confirmed
- Manufacturer identifier
- 0010037215
Prices and ordering
No recently checked price is available. Manufacturer’s current range.
How to compare heat pumps
Compare output and efficiency at the same outdoor and flow temperatures. Flow temperature is the temperature of the water sent to your radiators. A heat-loss survey determines the size you need. These listings cover outdoor units; controls, indoor components and usually a hot water cylinder complete the system.
Reviews from other sites
No matching review found. Last checked 28 October 2026.
Find an installer
By postcode
Find local heat pump installers and ask whether they fit Vaillant aroTHERM plus. Your enquiry will include this model.
Sources and documents
Manufacturer documents and UK supplier information.
- Vaillant product data sheet (EU 811/2013), aroTHERM plus 55 °C, doc 0020292189_02 — checked 28 October 2026
- Vaillant UK aroTHERM plus VWL 105/6 A 230V S2 ... VWL 125/6 A S2 operating, installation and maintenance instructions 0020330792_03 — checked 28 October 2026
- Vaillant UK aroTHERM plus product page — checked 28 October 2026
- City Plumbing: Vaillant Arotherm Plus 12Kw Heat Pump 0010037215 — checked 28 October 2026
- Vaillant aroTHERM plus technical information (UK; PDF metadata October 2020), as published on City Plumbing — checked 28 October 2026
Compare with a similar heat pump
- Vaillant aroTHERM plus — VWL 75/6 A 230V · 7 kW size · single-phase
- Samsung EHS Mono R290 — AE080CXYDEK · 8 kW size · single-phase
- Grant Aerona 290 — HPR29065 · 6.5 kW size · single-phase